Fire & Gas Engineer job at East African Crude Oil Pipeline (EACOP)
Posted by: great-volunteer
Posted date: 2025-Sep-02
Location: kampala, Kampala, Uganda
Fire & Gas Engineer 2025-09-01T13:53:03+00:00 East African Crude Oil Pipeline (EACOP) https://cdn.ugashare.com/jsjobsdata/data/employer/comp_11761/logo/download.png https://www.eacop.com/ FULL_TIME kampala Kampala 00256 Uganda Engineering Services Science & Engineering 2025-09-15T17:00:00+00:00 Uganda 8 Position Summary The Fire & Gas (F&G) Engineer is responsible for the implementation, testing, and commissioning of all F&G systems across EACOP substations and facilities. This includes the deployment of detection technologies (flame, heat, smoke, gas), alarm systems, suppression interfacing, and control panel configuration. The role ensures that all systems meet project safety requirements, functional design specifications, and compliance with Schneider Electric and oil & gas industry safety standards. Key Responsibilities - Supervise installation and perform field validation of fire and gas detection systems, including detectors, horns, strobes, and control panels.
- Configure and test F&G logic for alarm activation, shutdown signals, and interfacing with fire suppression or ESD (Emergency Shutdown) systems.
- Validate system layout and coverage based on hazardous area classification and project design drawings.
- Coordinate with instrumentation, SCADA, and ECS teams to ensure proper system integration and response logic.
- Perform loop checks, functional testing, and cause & effect validation.
- Ensure compliance with international fire & gas safety standards (e.g., NFPA, ISA, IEC 60079).
- Participate in Factory Acceptance Tests (FATs) and Site Acceptance Tests (SATs) for F&G panels and control interfaces.
- Troubleshoot system faults and alarms during commissioning and site acceptance.
- Maintain all F&G-related documentation including test reports, redlines, and O&M manuals.
- Support end-user training and system handover activities.
Qualifications & Experience Education - Bachelorâs degree in electrical, Electronics, or Instrumentation Engineering.
Years of Experience - Minimum 4â6 years of hands-on experience with F&G systems in oil & gas or hazardous industrial environments.
Industry Exposure - Field experience in energy infrastructure, terminals, or upstream/downstream facilities where F&G safety systems are mandatory.
Technical Tool/Software Proficiency - Familiarity with F&G control systems and configuration tools
- Microsoft Office Suite
- Basic understanding of DCS/PLC/SCADA integration
Technical Skills - Understanding of fire and gas detection principles (point and open-path gas detectors, smoke detectors, flame detectors, etc.).
- Knowledge of hazardous area classification and equipment selection.
- Ability to interpret cause & effect matrices, zoning layouts, and shutdown logic.
- Experience in loop checking, signal verification, and fault troubleshooting.
- Familiarity with integration of F&G systems with SCADA, PLCs, and shutdown systems.
Personal Attributes - Safety-driven mindset with a proactive approach to risk mitigation.
- Strong coordination and communication skills across disciplines.
- Meticulous in documentation and testing procedures.
- Able to work under pressure during commissioning or emergency readiness testing.
- Clear understanding of life-safety system criticality and regulatory compliance.
Preferred Additional Qualifications - Certification or training in fire & gas system design or maintenance (e.g., NFPA, ISA, or OEM specific).
- Experience with Schneider Electric F&G systems or similar platforms.
- Fluency in English is required; Swahili or French is a plus.
Performance Measurement (KPIs) - F&G loop completion and testing progress
- Number of false alarms or system errors during commissioning
- Compliance with safety and zoning standards
- Completion of cause & effect testing on schedule
- Documentation quality and handover package readiness
Work Conditions - Site-based across EACOP substations, pump stations, and terminal buildings.
- Work in hazardous zones with strict adherence to HSE and electrical safety standards.
- Full PPE compliance required; work may include elevated platforms and confined spaces.
- Possible extended hours during testing and system validation phases.
Supervise installation and perform field validation of fire and gas detection systems, including detectors, horns, strobes, and control panels. Configure and test F&G logic for alarm activation, shutdown signals, and interfacing with fire suppression or ESD (Emergency Shutdown) systems. Validate system layout and coverage based on hazardous area classification and project design drawings. Coordinate with instrumentation, SCADA, and ECS teams to ensure proper system integration and response logic. Perform loop checks, functional testing, and cause & effect validation. Ensure compliance with international fire & gas safety standards (e.g., NFPA, ISA, IEC 60079). Participate in Factory Acceptance Tests (FATs) and Site Acceptance Tests (SATs) for F&G panels and control interfaces. Troubleshoot system faults and alarms during commissioning and site acceptance. Maintain all F&G-related documentation including test reports, redlines, and O&M manuals. Support end-user training and system handover activities. Education Bachelorâs degree in electrical, Electronics, or Instrumentation Engineering. Years of Experience Minimum 4â6 years of hands-on experience with F&G systems in oil & gas or hazardous industrial environments. Industry Exposure Field experience in energy infrastructure, terminals, or upstream/downstream facilities where F&G safety systems are mandatory. JOB-68b5a53f33f5b Vacancy title: Fire & Gas Engineer Jobs at: East African Crude Oil Pipeline (EACOP) Deadline of this Job: Monday, September 15 2025 Duty Station: kampala | Kampala | Uganda Summary Date Posted: Monday, September 1 2025, Base Salary: Not Disclosed JOB DETAILS: Position Summary The Fire & Gas (F&G) Engineer is responsible for the implementation, testing, and commissioning of all F&G systems across EACOP substations and facilities. This includes the deployment of detection technologies (flame, heat, smoke, gas), alarm systems, suppression interfacing, and control panel configuration. The role ensures that all systems meet project safety requirements, functional design specifications, and compliance with Schneider Electric and oil & gas industry safety standards. Key Responsibilities - Supervise installation and perform field validation of fire and gas detection systems, including detectors, horns, strobes, and control panels.
- Configure and test F&G logic for alarm activation, shutdown signals, and interfacing with fire suppression or ESD (Emergency Shutdown) systems.
- Validate system layout and coverage based on hazardous area classification and project design drawings.
- Coordinate with instrumentation, SCADA, and ECS teams to ensure proper system integration and response logic.
- Perform loop checks, functional testing, and cause & effect validation.
- Ensure compliance with international fire & gas safety standards (e.g., NFPA, ISA, IEC 60079).
- Participate in Factory Acceptance Tests (FATs) and Site Acceptance Tests (SATs) for F&G panels and control interfaces.
- Troubleshoot system faults and alarms during commissioning and site acceptance.
- Maintain all F&G-related documentation including test reports, redlines, and O&M manuals.
- Support end-user training and system handover activities.
Qualifications & Experience Education - Bachelorâs degree in electrical, Electronics, or Instrumentation Engineering.
Years of Experience - Minimum 4â6 years of hands-on experience with F&G systems in oil & gas or hazardous industrial environments.
Industry Exposure - Field experience in energy infrastructure, terminals, or upstream/downstream facilities where F&G safety systems are mandatory.
Technical Tool/Software Proficiency - Familiarity with F&G control systems and configuration tools
- Microsoft Office Suite
- Basic understanding of DCS/PLC/SCADA integration
Technical Skills - Understanding of fire and gas detection principles (point and open-path gas detectors, smoke detectors, flame detectors, etc.).
- Knowledge of hazardous area classification and equipment selection.
- Ability to interpret cause & effect matrices, zoning layouts, and shutdown logic.
- Experience in loop checking, signal verification, and fault troubleshooting.
- Familiarity with integration of F&G systems with SCADA, PLCs, and shutdown systems.
Personal Attributes - Safety-driven mindset with a proactive approach to risk mitigation.
- Strong coordination and communication skills across disciplines.
- Meticulous in documentation and testing procedures.
- Able to work under pressure during commissioning or emergency readiness testing.
- Clear understanding of life-safety system criticality and regulatory compliance.
Preferred Additional Qualifications - Certification or training in fire & gas system design or maintenance (e.g., NFPA, ISA, or OEM specific).
- Experience with Schneider Electric F&G systems or similar platforms.
- Fluency in English is required; Swahili or French is a plus.
Performance Measurement (KPIs) - F&G loop completion and testing progress
- Number of false alarms or system errors during commissioning
- Compliance with safety and zoning standards
- Completion of cause & effect testing on schedule
- Documentation quality and handover package readiness
Work Conditions - Site-based across EACOP substations, pump stations, and terminal buildings.
- Work in hazardous zones with strict adherence to HSE and electrical safety standards.
- Full PPE compliance required; work may include elevated platforms and confined spaces.
- Possible extended hours during testing and system validation phases.
Work Hours: 8 Experience in Months: 48 Level of Education: bachelor degree Job application procedure Interested in applying for this job? truenorthafrica.com&form%5Bvalid-to%5D=Monday,%20September%2015%202025">Click here to submit your application now.
|